Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Rev. Salusvita (Online) ; 28(1): 31-39, 2009. graf, tab
Article in Portuguese | LILACS | ID: lil-582292

ABSTRACT

This study evaluates the marginal microleakage of resin modified glass ionomer – Vitremer/3M, used as temporary sealer after endodontic treatment. 36 molars were selected, in which, after endodontic treatment, cavities with 4mm of depth were standardized for the sealer material insertion, and divided into two groups of 18 teeth each: Group1 (conventional technique): primer + glass ionomer+ protective of surface and Group2 (hybridization technique): 37 per centphosphoric acid + adhesive system Single Bond + glass ionomer+ protective of surface. After restoration, all the specimens were thermocycled, impermeabilized and immersed in 2 per cent of methylene blue solution for 7 days...


Este estudo avaliou a infiltração marginal do ionômero de vidro modifi cado por resina – Vitremer, utilizado como selador provisório após tratamento endodôntico. Foram selecionados 36 molares íntegros, nos quais, após o tratamento endodôntico, padronizou-se cavidades com 4mm de profundidade para inserção do material selador; originando dois grupos com 18 corpos-de-prova cada: Grupo 1 (técnica convencional) primer + ionômero + protetor de superfície e Grupo 2 (técnica com hibridização) ácido fosfórico 37 por cento + adesivodentinário Single Bond + ionômero + protetor de superfície. Procedeu-se então a termociclagem e em seguida a imersão em azul de metileno a 2 por cento por 7 dias...


Subject(s)
Humans , Male , Female , Glass Ionomer Cements/chemistry , Endodontics , Dental Leakage/diagnosis
2.
Rev. Salusvita (Online) ; 28(1): 21-29, 2009. graf, tab
Article in English | LILACS | ID: lil-582293

ABSTRACT

O propósito deste estudo foi avaliar radiograficamente a qualidade dos retentores intra-radiculares, região periapical e tratamentos endodônticos. Um total de 192 radiografias periapicais foram selecionadas da Clínica Odontológica do Centro Universitário do ParᖠCESUPA. De acordo com os critérios radiográficos, a qualidade foi categorizada como adequada ou inadequada. Os dados analisados por meio do teste estatístico X2 demonstraram que o tratamento endodôntico apresentou inadequado em 53.64 por cento; a região periapical foi inadequada em 34.89 por cento; os elementos reabilitadores presentes apresentaram adaptação cervical inadequada em 51.85 por centoe os retentores intra–radiculares foram executados inadequadamente em 58.33 por cento...


The purpose of this study was to evaluate the quality of the coronalrestoration, radicular retainer, periapical status and root fi llingsscored on radiographic basis of endodontically treated teeth. Atotal of 192 periapical radiographs were randomly selected from CESUPA´S Dental School patients. According to the radiographic criteria, the technical quality was categorized as ´adequate` or ´inadequate`. The data analyzed by statistical X2 test demonstratedthat 53.64 per cent had inadequate endodontic treatment; teeth with anadequate root fi lling were associated with a better periapical statusthan teeth with inadequate root fi lling (65.1 per cent vs. 34.89 per cent); teeth with adequate and inadequate coronal restorations were 48,14 per cent and 51.85 per cent, respectively. This difference was not statistically signifi cant and the rate of inadequate root canal post and core was 58.33 per cent.


Subject(s)
Humans , Dental Implantation, Endosseous, Endodontic
3.
Rev. Salusvita (Online) ; 28(2): 129-134, 2009.
Article in English | LILACS | ID: lil-583118

ABSTRACT

This study evaluated the influence of storage solution on bovine enamel. Forty freshly extracted bovine incisor teeth were used. The teeth were divided into four groups (n=10) following conditions, for 90 days: G1 = distilled water (control group); G2 = artificial saliva; G3 = 0,1 per cent thymol; G4 = saline solution. After storage, the specimens were observed under a scanning electron microscope. The comparative analysis of the specimens revealed a great variation in the structure pattern of the normal enamel...


O objetivo deste estudo foi analisar in vitro as possíveis alterações estruturais do esmalte bovino, após o armazenamento em diferentes soluções. Foram utilizados 40 espécimes bovinos que foram divididos em quatro grupos (n=10) e armazenados nas seguintes condições, por 90 dias: G1= água destilada (controle); G2= saliva artifi cial; G3= timol a 0,1 por cento; G4= soro fisiológico. Decorrido o prazo experimental os corpos-de-prova foram analisados por meio da microscopia eletrônica de varredura. A análise comparativa dos corpos-de-prova revelou uma grande variação no padrãomorfológico da superfície do esmalte normal...


Subject(s)
Animals , Materials and Supplies Stockpiling , Tooth , Dental Enamel , Thymol
4.
Odontol. clín.-cient ; 7(4): 285-288, out.-dez.2008.
Article in Portuguese | LILACS, BBO | ID: lil-505591

ABSTRACT

O presente trabalho teve por meta revisar a literatura pertinente à restauração com materiais ionoméricos na prática odontológica. Foram considerados aspectos relativos como, características e propriedades físico-química dos ionômeros de vidro restauradores, assim como o conhecimento atual de técnicas alternativa para aplicação destes materiais.


The present work had for goal to revise the pertinent literature tho the restoration with ionomeric materials in dental practice. Relative aspects were considered such as, physiochemical characterístics and properties of the glass restorers' ionomer, as current knowledge of alternative techniques for application of these materials.


Subject(s)
Dental Leakage , Dental Materials , Esthetics, Dental , Glass Ionomer Cements
5.
Rev. Salusvita (Online) ; 27(1): 45-54, 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-562316

ABSTRACT

Este artigo teve como objetivo avaliar a qualidade de limpeza de canais simulados instrumentados com o sistema de rotação contínua K3 Endo (Grupo 1) e um sistema de rotação alternada NSK, com limas tipo K-Flexofi le (Grupo 2). Trinta canais simulados, previamente corados, com curvatura de 30º foram divididos em doisgrupos e instrumentados pelos diferentes sistemas, auxiliados pelo creme Endo-PTC e solução de hipoclorito de sódio a 0,5%. Após a instrumentação, os blocos de resina foram posicionados no sentidovestíbulo-lingual e fotografados, com uma câmera digital Sony-H1. Em seguida, realizou-se a análise das imagens, observando-se visualmente as paredes externa e interna nos terços médio e apical por meio do programa Adobe Photoshop 7.0.1. A análise dos resultados(X2 e Exato de Fisher) demonstrou que nenhuma das técnicas limpoucompletamente as superfícies das paredes dos canais. A rotação contínuademonstrou melhor limpeza na parede externa, enquanto que no terço apical o resultado entre as técnicas não foi signifi cante. Já na parede interna, não houve diferença signifi cante entre as técnicasestudadas, nos dois terços avaliados. Os autores concluem que o sistema de rotação contínua apresentou melhor limpeza no terço médio do canal simulado (p<0,05). O terço apical foi o menos limpo por ambas as técnicas de instrumentação.


The aim of this study was to compare the cleaning effectiveness of K3 Endo system (Group 1) and the alternated rotation system – NSK, combined with flexible files (Group 2), during the preparation of simulated curved root canals. 30 simulated roots were divided into two groups and prepared according to each technique. After each instrumentation, the root canals were flushed with 0,5 percent NaOCl solution and Endo-PTC cream. Post instrumentation images were recorded, and the assessment of the canal shape was completed with a computer image analysis program. The analysis of the results (X² e Fisher’s exact) showed that cleanliness was not satisfactory in both systems (p < 0.05).


Subject(s)
Dental Instruments , Dentistry , Root Canal Preparation/instrumentation
6.
Rev. Salusvita (Online) ; 27(2): 83-98, 2008. tab, graf
Article in Portuguese | LILACS | ID: lil-562304

ABSTRACT

O presente estudo avaliou in vitro a infiltração marginal de dois materiais restauradores utilizados como seladores provisórios após tratamento endodôntico. Foram selecionados 40 molares íntegros, nos quais, após o tratamento endodôntico, padronizou-se cavidades com 4mm de profundidade e 2mm de espessura de parede dentária bpara inserção do material selador; originando dois grupos com 20 corpos-de-prova cada: Grupo I - Coltosol e Grupo II - Vitremer. Procedeu-se então a termociclagem e a impermeabilização dos espécimes, onde foi aplicado o cianocrilato em toda a superfície do dente, com exceção de 1 mm da interface dente/material. Logo após, metade de cada grupo foi imerso no corante azul de metileno a 2 por cento, com ph 7,2, por 7 dias, enquanto que a outra metade permaneceu imerso na solução corante por 30 dias...


This in vitro study evaluated the marginal leakage of two temporary coronal filling materials after root canal treatment. Standardized cavities accesses were prepared in 40 intact human permanent molar teeth. They were divided into two groups consisting of 20 samples. The teeth were restored using one of the temporary filling materials, namely: Coltosol and Vitremer. After thermocycling, the experimental teeth applied on the coronal enamel, leaving a clear area of 1mm around the filling material. Then the samples were immersed in 2 percent methylene blue dye solution for leakage assessment


Subject(s)
Humans , Tooth Permeability
7.
Rev. Salusvita (Online) ; 27(2): 75-82, 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-562311

ABSTRACT

O objetivo deste trabalho foi avaliar a presença de desvio apical e a conicidade do preparo após a instrumentação de giro alternado NSK, utilizando-se limas tipo K-Flexofi le (Grupo 1) e instrumentação com o sistema Protaper (Grupo 2). Trinta canais simulados, com curvatura, foram divididos aleatoriamente em dois grupos e instrumentados pelos diferentes sistemas. A análise dos resultados (Exato de Fisher), obtidos de imagens por meio de uma plataforma radiográfica, demonstrou não haver diferença estatisticamente significante quanto à avaliação da presença de desvioentre os dois sistemas. No entanto, o instrumento Protaper manual obteve melhor qualidade de preparos dos canais radiculares (p<0,05).


The present study evaluated the presence of apical deviation and tapering in preparations performed with the use of the automated handpieces with alternate motion, the NSK (Group 1), and instrumentation manually with Protaper (Group 2). 30 simulated roots were divided into two groups and prepared according to each technique. The alteration caused by root canal preparation was analyzed by radiographs obtained by a radiographic desk specially made for the study. The results (Fisher’s exact) demonstrated that there wasn’t significant statistically differences between the two systems as to the evaluation of the presence of apical deviation. However, the system Protaper produced a greater tapering of the root canals (p<0,05).


Subject(s)
Dental Instruments , Root Canal Preparation/instrumentation , Root Canal Preparation
8.
Rev. Salusvita (Online) ; 27(3): 363-370, 2008. tab
Article in English | LILACS | ID: lil-566841

ABSTRACT

This in vitro study evaluated the coronal seal of two temporary coronal filling materials after root canal treatment. Standardized cavities accesses were prepared in 40 intact human permanent molar teeth. They were divided into two groups consisting of 20 samples.The teeth were restored using one of the following temporary filling materials, namely: Coltosol and Vitremer. After ther mocycling,the specimens were covered with cyanoacrylate, except over the coronal access. The samples were immersed in 2 percent methylene blue dye solution for 7 and 30 days. The teeth were sectioned and the greatest depth of dye penetration was recorded. The results showed no significantly differences between the groups (p>0,05). Under the condition of this study, the irrigants solutions during root-canaltreatment influenced coronal microleakage.


O presente estudo avaliou o selamento coronário de dois materiais restauradores utilizados como seladores provisórios após tratamento endodôntico. Foram selecionados 40 molares íntegros, nos quais, após o tratamento endodôntico, padronizou-se cavidades para inserção do material selador; originando dois grupos com 20 corpos-de prova cada: Grupo I - Coltosol e Grupo II - Vitremer. Procedeu-se então a termociclagem e a impermeabilização dos espécimes, onde foi aplicado o cianocrilato em toda a superfície do dente, com exceção de 1 mm da interface dente/material. Logo após, metade de cada grupo foi imerso no corante azul de metileno a 2 percent, com pH 7,2, por7 dias, enquanto que a outra metade permaneceu imerso na solução corante por 30 dias. Em seguida, os corpos-de-prova foram seccionados e levados à leitura. Os resultados demonstraram não haver diferença estatística significante entre os grupos experimentais nos períodos observados (p>0,05). Conclui-se que, a adaptação do material provisório às paredes dentinárias sofre influência da ação préviado tratamento químico cirúrgico destas paredes.


Subject(s)
Humans , Male , Female , Endodontics , Dental Leakage , Dental Materials , Dentistry
9.
RGO (Porto Alegre) ; 55(3): 1-4, jul.-set. 2007. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-519076

ABSTRACT

O objetivo deste trabalho foi avaliar a limpeza de canais simulados instrumentados manualmente com limas de Níquel-Titânio û Protaper (Grupo 1) e um sistema de rotação alternada NSK, com limas tipo K-Flexofile (Grupo 2). Trinta canais foram divididos em dois grupos e instrumentados pelos diferentes sistemas. A análise dos resultados (X2 e Exato de Fisher), obtidos de imagens digitalizadas, demonstraram que nenhuma das técnicas limpou completamente as superfícies das paredes dos canais. Numa comparação entre a Protaper manual e rotação alternada houve diferença apenas no terço médio, no qual a lima Protaper manual se mostrou melhor (p<0,05).


Subject(s)
In Vitro Techniques , Root Canal Preparation/instrumentation , Root Canal Preparation/methods
10.
RGO (Porto Alegre) ; 55(1): 23-28, jan.-mar. 2007. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-462951

ABSTRACT

Objetivos: Avaliar in vitro a efetividade antimicrobiana dos alginatos autodesinfetantes quando comparados aos alginatos convencionais, às soluções desinfetantes de hipoclorito de sódio a 1 % e clorexidina a 2%. Métodos: O método da difusão em ágar foi empregado; microorganismos utilizados para o ensaio experimental foram o Streptococcus mutans e Staphylococcus aureus. Resultados: Uma marcante diferença entre os alginatos foi encontrada. O hidrocolóide irreversível contendo clorexidina, as soluções de hipoclorito de sódio a 1 % e clorexidina a 2% exibiram atividade antimicrobiana para os Streptococcus mutans. Conclusão: No entanto, somente as soluções de hipoclorito de sódio a 1 % e clorexidina a 2% exibiram eficácia quanto a ação antimicrobiana para os Staphylococcus aureus, tendo o alginato autodesinfetante se mostrado resistente para este tipo de microorganismo.


Subject(s)
Environmental Pollution , Chlorhexidine/administration & dosage , Dental Impression Materials , Disinfection , Sodium Hypochlorite/administration & dosage , In Vitro Techniques
11.
Rev. odontol. UNESP ; 36(1): 91-96, jan.-mar. 2007. ilus, graf, tab
Article in Portuguese | LILACS, BBO | ID: lil-529258

ABSTRACT

O objetivo deste estudo foi avaliar a infiltração coronária de dois materiais restauradores provisórios utilizados em Endodontia: Coltosol (grupo I) e Vitremer (grupo II). Foram utilizados 20 molares, divididos em dois grupos, cada um deles recebendo um dos materiais avaliados. Todos os espécimes foram termociclados, impermeabilizados e imersos em corante por 7 dias. Posteriormente, os corpos-de-prova foram lavados em água corrente e seccionados longitudinalmente para avaliação das infiltrações em milímetros na interface dente/material restaurador e pela massa do material por meio de uma lupa estereoscópica. A análise dos dados (Mann-Whitney) mostrou que o Vitremer promoveu o melhor selamento (p < 0,05). Concluiu-se que a espessura do selador provisório é um fator de grande relevância na determinação do selamento.


The objective of this study was to evaluate the coronal leakage of two temporary sealer used in Endodontics: Coltosol (group I) and Vitremer (group II). Twenty molars were selected, subdivided into two groups, each one of them receiving one of the appraised materials. All of the specimens were thermocycled, impermeabilized and immersed in 2% methylene blue solution for 7 days. After this period, the samples were washed in current water and sectioned mesiodistally for evaluation of the infiltrations in millimeters between tooth/material and from the body of material. The analysis of the data (Mann-Whitney) showed that Vitremer provides the best sealing (p < 0.05). In conclusion, the thickness of the temporary filling material is a factor of great relevance in the determination of the filling.


Subject(s)
Glass Ionomer Cements , Endodontics
SELECTION OF CITATIONS
SEARCH DETAIL